29
c/boilermakers•ward.piperward.piper•5d ago

Finally got that old boiler feed pump in Toledo to stop leaking

It was a real mess last Thursday when the packing gland on the main feed pump at the old plant on Summit Street started spraying hot water. I had to shut it down and replace all the packing rings, which took about four hours in that tight space. Has anyone found a better packing material than the standard graphite stuff for high pressure steam?
2 comments

Log in to join the discussion

Log In
2 Comments
danielh81
danielh815d ago
Know exactly what you mean, that's a brutal job in a tight spot. @luna617 is right, it's always something with the old gear. For high pressure steam, we've had good luck with the braided Teflon style packing, seems to hold up a bit longer before it needs another crank.
3
luna617
luna6175d ago
Man, that's the story of every old piece of gear now.
2